Setting up a new POS AV with the MIDAS.


Before use with the MIDAS you need to set up your new POS as follows:

  1. Start the POS AV (press and hold the Start button for a few seconds).
  2. Start the POS AV Controller program on the MIDAS Pilot Display.
  3. Press the Connect button.
  4. Go toMenu > Settings > Input/Output Ports > Serial/Analog
  5. Go to the COM1 tab and Enable COM1, set the Baud rate at 115200, no Parity, 8 data bits, 1 stop bit, update rate 5Hz.
  6. Message select (only): $INVTG, $INGGA, $INZDA.
  7. Press Apply and the window.
  8. Go to Menu > Settings > Save Settings. A window with a blue progress bar should appear, confirming the settings have been saved.
  9. Warning: Make sure Logging is OFF before saving the setting.
  10. Press the Disconnect button.
  11. Now cycle power the POS AV and check if the settings you just made are still there.